Combustion Air-To-Flue Gas Heat Pipe Heat Exchanger

  • Manufactured by CE Air Preheater Co.
  • Counterflow design, single pass
  • 1,260,000 Btu/h transferred

Combustion Air Side

  • 19,700 lb/h
  • 530oF inlet temperature
  • 303oF outlet temperature
  • 18,000 lb/h
  • 70oF inlet temperature
  • 361oF outlet temperature

Key Contact

Bruce Miller

(814) 865-3093