Phosphosilicate Glass Etch
During the phosphorus predep a layer of phosphosilicate glass was grown on the surface of the silicon. This layer will act as a constant source of dopants for subsequent diffusion steps, thus fixing the surface concentration of the phosphorus doped areas to the solid solubility limit.
In order to remove the PSG, a three step etch will be performed:
remove BSG: HF etch
chemical oxidation: H
2SO
4/HNO
3 remove chemically oxidized layer: HF etch
Equipment
- Acid fume hood
- Polypropylene boat with handle
Supplies
- 50:1 DI water:HF oxide etch
- HF rinse tank filled with DI water
- Glass etch: 1:1 H2SO4:HNO3
- Glass etch rinse tank filled with DI water
- Final rinse tank filled with DI water
Operating parameters
- 50:1 oxide etch time: 20 seconds
- HF Rinse time: 5-10 seconds
- Final Rinse time: 10-20 seconds
- Glass etch time: 600 seconds
- Glass etch rinse time: 5-10 seconds
- Final Rinse time: 10-20 seconds
- 50:1 oxide etch time: 20 seconds
- HF Rinse time: 5-10 seconds
- Final Rinse time: 10-20 seconds
Equipment/controls/tools locations
All equipment is located in rm50S (wet lab)
- Acid etch hood:
- Etching boat
- 50:1 oxide etch
- Glass etch
- Glass etch rinse tub
- HF rinse tub
- Final rinse tub
Operating precautions
Chemical hazard
The 50:1 oxide etch and glass etch are extremely hazardous. Use with extreme caution, and only with appropriate personal protective equipment (safety glasses, face shield, latex gloves, and nitrile gloves). Use only under a fume hood. Treat exposure as described in the safety sections.
Only handle the gloves from the inside. Assume anything that is wet is either extremely acidic or basic. Do not lean on fume hoods.
Operating procedure
Phosphosilicate glass should be considerably easier to remove than phosphosilicate glass, but we'll use the same procedure to remove it. High surface concentrations of phosphorus are detrimental to photoresist adhesion so it is imperative that we remove it all.
- Remove the phosphosilicate glass by placing the wafer in the 50:1 DI:HF oxide etch for 20 seconds. Follow with a thorough DI rinse.
- Immerse the wafer in 1 H2SO4 : 1 HNO3 for 600 seconds to oxidize the elemental boron.
- Rinse thoroughly with DI water and return to the 50 DI:1 HF oxide etch for another 20 seconds to remove the oxidized boron.
- Wash very thoroughly in DI water and dry carefully with N2.
- Use the hot point probe to verify that the largest test area (on left) has indeed been changed back to N-type. Consult your instructor if it did not.
Type ____________
Average Rs2 = ____________ Ω/sq
Enter your Rs values and furnace boat position into your logsheet ASAP using the LDS 4PP software.
When entering data into the logsheet for boron predep, an SPC chart is generated showing the process limits. If your measured sheet resistance value lies between the top and bottom control limit lines then your wafer is within acceptable limits. If the measured value is out of this range consult your instructor. He or she may have you return your wafer to the boron predep furnace for an additional 10 minutes depending on the how far it's off. If this is required, the subsequent phosphosilicate glass removal times may be reduced proportionately.
Did the phosphosilicate glass removal affect the four-point probe measurement?
IC Process
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13. PSG Etch
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
Answers provided by this service may not be relevant to the materials presented in this website.
Department of Electrical and Computer Engineering
College of Engineering
University of Illinois Urbana-Champaign
Contact ece444
Copyright © 2007, 2008 The Board of Trustees at the University of Illinois. All rights reserved.
archives: ©1999 ©2000 ©2004 ©2005 ©2006